By 2025, numerous distribution-related standards and specifications had been issued or revised, providing guidance for upgrading distribution projects. For example, the "Design Specification for Photovoltaic Power Generation Connected to Distribution Networks" was established, applicable to the design of new and expanded photovoltaic power generation systems connected to distribution networks at voltage levels of 35kV and below. This specification covers key technical aspects, including photovoltaic power generation system connection design, main electrical wiring and electrical equipment parameter requirements for grid-connected substations, relay protection, safety and stability control devices, dispatching automation substation equipment, energy metering devices and remote energy terminals, system communications, and investment estimation. This means that in future distribution projects involving photovoltaic power generation connected to distribution networks, more stringent and detailed design standards will be implemented, helping to improve the safety and stability of photovoltaic power generation connected to distribution networks.
At the same time, the "Code for Design of Power Supply and Distribution Systems" (GB50052-2026) will be implemented on July 1, 2025, with the previous GB50052-95 being repealed. This code applies to the design of new, expanded, and renovated power supply and distribution systems ≤110 kV. It emphasizes that power supply and distribution system design must adhere to national technical and economic policies, ensure personal safety, ensure reliable power supply, utilize advanced technology, and be economically sound. The code requires a holistic and comprehensive approach to design, with a rational design plan determined based on load characteristics, power consumption, project characteristics, and regional power supply conditions. It also emphasizes a balance between short-term and long-term considerations, taking into account future development needs. Furthermore, electrical products that meet current national standards for high efficiency, energy conservation, advanced performance, environmental friendliness, safety, and reliability should be used. The implementation of these standards and codes will promote a more scientific and rational design approach for power distribution projects, laying the foundation for overall project upgrades.
The 2025 edition of the Technical Specifications for Temporary Electricity Safety at Construction Sites maintains the three-level distribution and two-level protection architecture for the power distribution system, but imposes stricter requirements on the functional positioning and technical parameters of distribution boxes at each level. As a core node on the power supply side, the main distribution box (cabinet) must be equipped with a circuit breaker with three-stage protection (overload, short circuit, and leakage). Its rated leakage operating current should be ≥30mA and the operating time should be ≥0.2s. These circuit breakers primarily provide system-level protection. This allows the main distribution box to better respond to various faults within the entire power distribution system, ensuring overall system safety.
As an intermediate link, the distribution box requires a branch circuit breaker. Its leakage protection function can be selected based on load characteristics, but it must be coordinated with the main distribution box and switch box in a differentiated manner. This differentiated coordination ensures effective fault isolation and protection between distribution boxes at different levels, preventing the escalation of faults. As the final distribution device, the switch box must have one switch, one leakage circuit breaker, and one box per machine. Its rated leakage operating current is ≤30mA (≤15mA when operating in a humid environment or metal container) and the operating time is ≤0.1s, ensuring that direct contact with the power source will disconnect within 0.1 seconds. This greatly improves operator safety and reduces the risk of electric shock accidents.
Notably, the new standard requires separate power and lighting systems. When power and lighting are combined, separate leakage protection must be installed in the lighting circuit to prevent secondary accidents caused by power equipment failures. This design optimizes the layout of the power distribution system and improves system reliability and safety.
In recent years, fires caused by aging cables have become a frequent occurrence. To prevent such incidents, the 2025 edition of the specification refines cable selection and installation requirements. The cable type must be selected based on the operating environment. Five-core rubber-insulated cables (YZ type) are recommended for general applications, while five-core polyvinyl chloride cables (YJV type) are recommended for humid locations or direct burial. Using a four-core cable with a PE conductor in place of a five-core cable is strictly prohibited. This is because different environments require different cable performance. The appropriate cable type can better adapt to the environment and reduce the probability of failure.
In terms of cable installation, strict cable selection requirements help improve cable life and safety. The standard also specifies cable bending radius, twisting, and extrusion avoidance. The bending radius of power cables should be no less than a certain multiple of their outer diameter, and twisting and extrusion should be avoided during installation to ensure proper operation. These detailed requirements ensure more standardized cable installation and improve the stability of the entire power distribution system.
The emergence of the 2025 Power Distribution Safety Regulations Examination Question Bank reflects the growing importance attached to power distribution safety regulations. In actual power distribution projects, strict adherence to safety regulations is key to ensuring the safety of personnel and equipment. For example, when performing electrical work, insulating rods that meet the voltage rating should be used, and their insulation resistance should not be lower than the specified value. Before using a tester, it should be tested on live equipment to confirm its sensitivity and insulation performance.
When performing electrical work during thunderstorms, avoid working at heights and wear insulated shoes and gloves to prevent lightning strikes. If electrical equipment catches fire, use an appropriate fire extinguisher, such as a dry powder or carbon dioxide extinguisher. Do not use water or foam extinguishers, as these can conduct electricity and escalate the incident. Furthermore, when using temporary grounding wires during electrical work, ensure they are properly grounded. When operating electrical equipment, ensure that parameters such as casing temperature, insulation, and voltage are within normal ranges. Strict adherence to these safety regulations can effectively reduce accidents and ensure the smooth progress of power distribution projects.
With the continuous advancement of technology, power distribution projects in 2025 will also show a trend of integrating with new technologies. On the one hand, the development of relevant regulations for the integration of photovoltaic power generation into distribution networks will promote the integration of renewable energy and distribution systems. As a clean energy source, the integration of photovoltaic power generation into distribution networks can reduce dependence on traditional energy sources and lower carbon emissions. Through the guidance of regulations, photovoltaic power generation systems can be more safely and stably connected to the distribution network, achieving optimal energy allocation.
Smart grid technology is also increasingly being applied to power distribution projects. Smart grids enable real-time monitoring, control, and optimization of distribution systems, improving power supply reliability and efficiency. For example, by installing smart meters and sensors, real-time electricity usage data can be collected, analyzing user behavior and load fluctuations, enabling precise power allocation. Smart grids also enable rapid fault diagnosis and isolation, reducing outages and improving user satisfaction.
The upgrade of power distribution engineering in 2025 will place new demands on the training and development of relevant talent. With the continuous updating of standards and the application of new technologies, the field of power distribution engineering requires professionals with professional knowledge and skills. For example, the new design specifications for photovoltaic power generation integrated into distribution networks require engineers with relevant knowledge of photovoltaic power generation systems and distribution networks to be able to design and optimize the system.
Regarding safety regulations, operators must master strict safety procedures and be equipped to respond to emergencies. To meet these needs, relevant training institutions and colleges should strengthen the cultivation of professionals specializing in power distribution engineering, offering relevant courses and practical sessions to enhance students' professional literacy and practical skills. At the same time, companies should also strengthen employee training and re-education, ensuring that employees stay up-to-date on the latest standards, specifications, and technologies to meet the needs of power distribution engineering upgrades.
Furthermore, the industry should encourage innovation and exchange to foster talent development. Technical seminars and academic exchange programs should be held to allow practitioners to share their experiences and latest research findings, thereby continuously elevating the technical capabilities of the industry as a whole. In short, talent is a key factor in driving the upgrade of power distribution projects, and cultivating and developing individuals who can adapt to the upgrade trends expected by 2025 is a crucial task for the industry's development.
|
|