Power transformation and distribution project of the training complex building of Guangxi Agricultural Vocational and Technical University
The training complex building in the West Campus of Guangxi Agricultural Vocational and Technical University needs to construct a supporting power transformation and distribution system. The core requirements of the project are:
Equipment configuration:
▶ High - voltage system: 4 KYN28 - 12 armored removable switchgear cabinets
▶ Low - voltage system: 17 SWGCS draw - out switchgear cabinets
▶ Photovoltaic access: 1 AP01 photovoltaic grid - connected cabinet (Delixi components, size 2000×700×600mm)
▶ Photovoltaic access: 22 sets of complete high - and low - voltage cabinets
Environmental conditions: The daily average humidity in Nanning area≤95% (based on the humidity standard in the equipment manual)
Functional goal: To carry the diversified power loads such as teaching training and photovoltaic grid - connection.
The plan advocates
Customer Value
1. KYN28 - 12 High - voltage switchgear
▶Multiple flanging process of aluminized zinc - coated steel plate(Corrosion - resistant)
▶Mechanical interlock meets\u201CFive - prevention\u201D
▶Cable chamber supports9 single - core cables
Anti - corrosion in high - humidity environment
Operation safety protection
Safe operation guarantee
No condensation alarm after commissioning (matching the humidity conditions in Nanning and the equipment protection design).
Mechanical interlock of high - voltage cabinet100% pass the “Five - prevention” verification.
Flexible expansion ability
The modular structure of the SWGCS cabinet supports later capacity expansion.
Efficient delivery of results
One-time successful power transmission.
2. SWGCS Low-voltage Switchgear Cabinet
▶Modular withdrawable structure(GB7251 standard)
▶Suitable forTemperature range: -15℃~40℃
▶Rated current up to6300A
Compact layout
Flexible load expansion
3.Photovoltaic grid - connected cabinet
▶Delixi - grade protection element
▶Customized photovoltaic support structure
1. Compatibility of power supply in multiple scenarios
It is necessary to simultaneously meet the access requirements of training equipment (impact load) and photovoltaic grid - connected (fluctuating power supply);
2.Safety risk
Non - professional personnel contacting high - voltage equipment are at risk of electric shock.
3. Space utilization limitations
The space in the power distribution room is limited, requiring the equipment to be compact and support later expansion.
|
|